Germany 161 m² SAC Automotive Components Cleanroom

Completed in Germany in 2024, this 161 m² SAC cleanroom provides an ISO 7 environment for automotive component operations.

Explore this application
Completed in Germany in 2024, this 161 m² project provided an ISO 7 clean environment for automotive component operations. The client required the clean space to fit an overseas site and its equipment layout, so the enclosure had to be coordinated with the building conditions rather than treated as a standalone box. The SAC modular cleanroom was assembled on site using a wall-and-ceiling package. Its scope also covered HVAC and filtration, lighting, electrical systems, automation, monitoring, commissioning, and validation. In this form of cleanroom construction, each cleanroom partition wall helps define the controlled area while service connections are planned around the operational footprint. The recorded delivery period was two months. The case demonstrates the use of a compact, site-assembled solution for an industrial application outside pharmaceuticals. It does not disclose the manufacturer, equipment specifications, or measured production outcomes.
Germany 161 m² SAC Automotive Components Cleanroom
161 m² Controlled area
2 months Delivery
ISO 7 Cleanroom class
01
THE CHALLENGE

Working Around Real Project Constraints

Provide approximately 161 m² of ISO 7 clean space for automotive component operations and adapt it to the overseas site and equipment layout.

02
THE SOLUTION

Engineered for the Process

A site-assembled SAC modular cleanroom provided 161 m² of ISO 7 space for automotive component operations in Germany.

SCOPE OF DELIVERY

A Coordinated Cleanroom Package

The project package was coordinated as a complete system, keeping architectural, mechanical and controls interfaces aligned from design through qualification.

  • 01Site-assembled modular walls and ceiling for a 161 m² automotive components cleanroom
  • 02HVAC and filtration serving the ISO 7 clean space
  • 03Lighting, electrical, automation and monitoring systems
  • 04On-site assembly, commissioning and validation
APPLICATION & SELECTION

Specifying an Automotive Cleanroom for an Overseas Site

For an overseas SAC installation, prepare one brief covering the component operation and the host building. Ask each project team to confirm its supply, installation and handover responsibilities against that brief.

Planning guidance for similar projects. The project snapshot and delivery scope above describe this case; the considerations below help define a new project brief.

Link the environment to component handling

Technical cleanliness extends beyond an isolated clean part. Review packaging, internal transport, personnel practices and assembly equipment as a connected chain, using the component specification to identify where protection is needed.

Check host-building interfaces before manufacture

Provide verified site dimensions, delivery routes, clear height and utility connection points. Ask the supplier and local installer to review penetrations, equipment openings, service access and the installation sequence together.

Agree the acceptance basis

Cleanroom performance tests depend on the selected test method and occupancy state. Record the applicable state, test scope and acceptance criteria in the handover plan so supplier, installer and owner use the same basis.

DEFINE YOUR REQUIREMENTS

What to share for a similar project

Use these inputs to discuss the layout, interfaces and delivery scope with our team.

Explore site-assembled (SAC) solutions
  • Building drawings, available dimensions and access restrictions
  • Process equipment layout and service connections
  • Air cleanliness and component acceptance requirements
  • Local installation scope and contractor interfaces
  • Documentation, test responsibilities and project schedule
PROJECT QUESTIONS

Planning an overseas automotive cleanroom

Does an ISO 7 room establish component cleanliness compliance?

Room air classification does not replace inspection of the component. Agree the component's particulate cleanliness specification and inspection records separately, using the applicable customer requirements.

What should an overseas installation enquiry include?

Send the building survey, installation address, access constraints, available utilities and local installation arrangements. State which drawings, instructions, training and handover documents you want included in the proposal.

How can the supply boundary be made clear?

Request a responsibility schedule identifying supplier work, local contractor work and owner work. Cover unloading, enclosure assembly, HVAC connections, electrical work, cleaning, testing and final acceptance, with exclusions stated explicitly.